R454B Condenser Units
What is R-454B?
R-454B refrigerant is one of the new refrigerants that are replacing R-410A in all residential and light commercial applications.
R-454B is a blend of refrigerants designed to provide efficient cooling while minimizing environmental impact. It is composed of hydrofluoroolefin (HFO) and hydrofluorocarbon (HFC) compounds, which work together to create a reliable and effective refrigerant.
A key property of R-454B refrigerant is its low global warming potential (GWP). Compared to older refrigerants, R-454B has a significantly lower GWP, meaning it has a reduced impact on climate change. This makes it a more sustainable choice for HVAC systems, aligning with the growing focus on environmental responsibility.
Overall, R-454B refrigerant provides a reliable and sustainable solution for HVAC systems. Its composition, properties, and benefits make it an excellent choice for residential and light commercial applications, delivering efficient cooling with reduced environmental impact.
SEER/SEER2 And HSPF/HSPF2
SEER2 is an updated rating standard introduced by the DOE. SEER2 standards are intended to provide a better gauge of typical home operating conditions whereas the older SEER rating utilized very precise protocols to determine ratings in ideal conditions. SEER2 standards include updated testing means that give a better indication of how a unit will operate in the real world.
HSPF2 is the newest type of rating system that expands on the basic HSPF scale.
Much like miles-per-gallon for a car, SEER/SEER2, EER/EER2, AFUE and HSPF/HSPF2 offer an easy way to compare efficiencies of different products – the higher the rating, the more efficient the unit. Just be sure you are comparing either SEER vs SEER or SEER2 vs SEER2 (same for EER/EER2 and HSPF/HSPF2).
EER2 versus SEER2
EER2 and SEER2 both evaluate an air conditioner’s energy efficiency, but they’re concerned with two different types of temperature conditions:
- EER2 measures an air conditioner’s efficiency at the peak cooling temperature of 95°F.
- SEER2 measures an air conditioner’s efficiency throughout an entire cooling season, with temperatures ranging from 65°F to 104°F.
The DOE’s regional breakdown by state is as follows:
- North
- 15.0 SEER/ 14.3 SEER2
- 8.0 HSPF/6.7 HSPF2
- 90% AFUE
- Southeast
- 14.0 SEER/ 13.4 SEER2
- 8.0 HSPF/6.7 HSPF2
- 80% AFUE
- Southwest
- 14.0 SEER/ 13.4 SEER2
- 8.0 HSPF/6.7 HSPF2
- 80% AFUE
To meet the SEER2 requirements in the southeast region, residential central air systems below 45,000 Btu must have a SEER2 rating of 14.3 (15.0 SEER). Residential central air systems 45,000 Btu and above must have a SEER2 rating of 13.8 (14.5 SEER). We currently offer a line of air conditioners that start at the minimum efficiency available and go all the way up to a 19 SEER2. Depending on your average usage, higher SEER2 air conditioners can significantly reduce your electric bill.
Additionally, we offer many air conditioners that have advanced features, such as 2-stage compressors and variable speed fan operation. These features not only improve the comfort level of your home, but can provide additional energy savings as well.
Click Here for more information on the Endeavor® Line Ultra™ Series iM Air Conditioner.
Click Here for more information on the Endeavor™ Line Achiever® Plus Series Air Conditioner.
Click Here for more information on the Endeavor™ Line Achiever® Series Air Conditioner.
Click Here for more information on the Endeavor™ Line Achiever® Series Air Conditioner
Air Conditioning Product Offering
UA19AY Endeavor® Line Ultra™ Series iM Air ConditionersView Brochure |
|---|
| Model Family: UA19AY |
| Efficiency SEER2: up to 20 SEER2 |
| Efficiency EER2: up to 13 EER2 |
| Energy Star Certified: ENERGY STAR® |
| Sound Level: As low as 57 dB |
| Refrigerant Type: R-454B Refrigerant |
| Compressor: Inverter Driven, Variable Speed |
| Factory Warranty Parts: Parts Ten (10) Year Warranty |
| Factory Warranty Compressor: Conditional Unit Replacement (Registration Required)-10 Years |
Manufacturer's Stated Benefits:
|
UA16AY Endeavor™ Line Achiever® Plus Series Air ConditionerView Brochure |
|---|
| Model Family: UA16AY |
| Efficiency SEER2: 17 SEER2 |
| Efficiency EER2: 12.0 EER2 |
| Energy Star Certified: ENERGY STAR® |
| Sound Level: As low as 72 dBA |
| Refrigerant Type: R-454B |
| Compressor: Two-Stage |
| Factory Warranty Parts: Conditional Parts (Registration Required)..................................Ten (10) Years |
| Factory Warranty Compressor: Conditional Parts (Registration Required)..................................Ten (10) Years |
Manufacturer's Stated Benefits:
|
RA14AY Endeavor™ Line Achiever® Series Air ConditionerView Brochure |
|---|
| Model Family: RA14AY |
| Efficiency SEER2: 15.2 SEER2 |
| Efficiency EER2: 12 EER2 |
| Energy Star Certified: ENERGY STAR® |
| Sound Level: As low as 70 dB |
| Refrigerant Type: R-454B |
| Compressor: Single Stage Scroll Compressor |
| Factory Warranty Parts: 10 Year Conditional Parts |
| Factory Warranty Compressor: 10 Year Conditional Parts |
Manufacturer's Stated Benefits:
|
WA13NY Endeavor Line Choice Series Air ConditionerView Brochure |
|---|
| Model Family: WA13NY |
| Efficiency SEER2: 13.4 SEER2 |
| Efficiency EER2: 9.0 EER2 |
| Energy Star Certified: No |
| Sound Level: As low as 68 dB |
| Refrigerant Type: R-454B |
| Compressor: Single Stage |
| Factory Warranty Parts: Conditional Parts (Registration Required): Ten (10) Years |
| Factory Warranty Compressor: Conditional Parts (Registration Required): Ten (10) Years |
Manufacturer's Stated Benefits:
|